AS/NZS Single Core 3.8/6.6KV XLPE Insulated
Description

Application:
       This cable is used for urban networks. It can be installed aerially, in conduit, on open trays and in underground ducts 
Operating temperature:
       90 & & &,,,,,
 
Voltage rating:
       3.8/6.6KV
Construction:
      Conductor: Compact round stranded copper or aluminium
      Conductor Shield: Semi-conducting tape and /or semi-conducting cross-linked polyethylene
      Insulation: Cross-linked polyethylene
      Insulation Shield: Semi-conducting cross-linked polyethylene
      Shield: Copper wire shield
       Filler: Polypropylene (Nonhygroscopic material)
       Binding Tape: Polyester and/or non-woven tape (Optional: water blocking tape)
      Sheath: Black polyvinylene (Optional: polyvinyl chloride)

Insulation colour:
     Natural

Followed standard:
      AS/NZS1429.1,AS/NZS1125
Construction data: 
      
Copper conductor,10KA Fault Level
 

Nominal Cross sectional area

Reference conductor diameter Nominal insulation thickness Nominal diameter over insulation Nominal screen area on each core Number and nominal diameter of screen wires Nominal over screen wire Approx overall diameter Approx weight of cable Max.
puling tension
Min.bending radius
During pulling Set in position
mm2 mm mm mm mm2 mm mm mm kg/km KN mm mm
16 4.8 2.5 11.0 15.9 28/0.85 14.3 18.4 540 1.1 330 220
25 6.0 2.5 12.0 24.4 43/0.85 15.3 19.4 720 1.8 350 230
35 7.1 2.5 13.0 34.4 24/1.35 17.3 21.4 930 2.5 380 260
50 8.4 2.5 14.1 48.7 34/1.35 18.4 22.5 1205 3.5 410 270
70 10.0 2.5 15.7 68.1 30/1.70 20.7 25.0 1605 4.9 450 300
95 11.7 2.5 17.6 68.1 48/1.35 22.6 26.9 1905 6.7 480 320
120 13.2 2.5 19.2 68.7 48/1.35 23.5 27.6 2150 8.4 500 330
150 14.5 2.5 20.6 68.7 48/1.35 24.9 29.0 2455 11 520 350
185 16.2 2.5 22.2 68.7 48/1.35 26.5 30.8 2755 13 550 370
240 18.4 2.5 24.9 68.7 48/1.35 29.2 33.7 3355 17 610 400
300 20.6 2.5 27.6 68.7 48/1.35 31.9 36.6 4005 21 660 440
400 23.8 2.5 30.9 68.7 48/1.35 35.2 40.2 5005 28 720 480

















 







      Aluminum conductor,10KA Fault Level

Nominal Cross sectional area

Reference conductor diameter Nominal insulation thickness Nominal diameter over insulation Nominal screen area on each core Number and nominal diameter of screen wires Nominal over screen wire Approx overall diameter Approx weight of cable Max.
puling tension
Min.bending radius
During pulling Set in position
mm2 mm mm mm mm2 mm mm mm kg/km KN mm mm
35 7.1 2.5 13.0 22.7 40/0.85 16.3 20.4 600 1.8 370 250
50 8.4 2.5 14.1 32.9 23/1.35 18.5 22.6 765 2.5 410 270
70 10.0 2.5 15.7 45.8 32/1.35 20.1 24.2 975 3.5 440 290
95 11.7 2.5 17.6 61.5 43/1.35 21.8 25.9 1205 4.8 470 310
120 13.2 2.5 19.2 68.7 48/1.35 23.2 27.3 1400 6.0 490 330
150 14.5 2.5 20.6 68.7 48/1.35 24.7 28.7 1500 7.5 520 340
185 16.2 2.5 22.2 68.7 48/1.35 26.3 30.4 1600 9.3 550 360
240 18.4 2.5 24.9 68.7 48/1.35 28.8 33.1 1855 12.0 600 400
300 20.6 2.5 27.6 68.7 48/1.35 31.5 36.0 2105 15.0 650 430
400 23.8 2.5 30.9 68.7 48/1.35 34.8 39.5 2455 20.0 710 470