AS/NZS Single Core 6.35/11KV XLPE Insulated
Description

Application:
       This cable is used for urban networks. It can be installed aerially, in conduit, on open trays and in underground ducts 
Operating temperature:
       90 & & &,,,,,
 
Voltage rating:
       6.35/11KV
Construction:
      Conductor: Compact round stranded copper or aluminium
      Conductor Shield: Semi-conducting tape and /or semi-conducting cross-linked polyethylene
      Insulation: Cross-linked polyethylene
      Insulation Shield: Semi-conducting cross-linked polyethylene
      Shield: Copper wire shield
       Filler: Polypropylene (Nonhygroscopic material)
       Binding Tape: Polyester and/or non-woven tape (Optional: water blocking tape)
      Sheath: Black polyvinylene (Optional: polyvinyl chloride)

Insulation colour:
     Natural

Followed standard:
       AS/NZS1429.1,AS/NZS1125
Construction data: 
      
Copper conductor,10KA Fault Level   
 

Nominal Cross sectional area

Reference conductor diameter Nominal insulation thickness Nominal diameter over insulation Nominal screen area on each core Number and nominal diameter of screen wires Nominal over screen wire Approx overall diameter Approx weight of cable Max.
puling tension
Min.bending radius
During pulling Set in position
mm2 mm mm mm mm2 mm mm mm kg/km KN mm mm
16 4.8 3.4 12.8 15.9 28/0.85 16.1 20.3 590 1.1 360 240
25 6.0 3.4 13.8 24.4 43/0.85 17.1 21.5 780 1.8 380 250
35 7.1 3.4 14.8 34.4 24/1.35 19.1 23.5 990 2.5 420 280
50 8.4 3.4 16.0 48.7 34/1.35 20.4 24.5 1255 3.5 440 290
70 10.0 3.4 17.6 68.1 30/1.70 22.5 27.0 1655 4.9 480 320
95 11.7 3.4 19.5 68.7 48/1.35 23.8 28.0 1955 6.7 500 330
120 13.2 3.4 21.0 68.7 48/1.35 25.5 29.5 2255 8.4 530 350
150 14.5 3.4 22.5 68.7 48/1.35 26.8 31.2 2555 11.0 560 370
185 16.2 3.4 24.2 68.7 48/1.35 28.5 33.0 2850 13.0 590 390
240 18.4 3.4 26.5 68.7 48/1.35 30.9 35.5 3450 17.0 640 420
300 20.6 3.4 29.0 68.7 48/1.35 33.3 38.0 4105 21.0 680 450
400 23.8 3.4 31.8 68.7 48/1.35 36.5 41.5 5055 28.0 740 490
500 26.5 3.4 34.8 68.7 48/1.35 39.3 44.5 6055 35.0 800 530
630 30.0 3.4 38.5 68.7 48/1.35 43.0 49.0 7300 44.0 880 580
800 36.0 3.4 44.5 68.7 48/1.35 49.0 55.0 9250 56.0 990 660
 

 
       
         Aluminum conductor,10KA Fault Level

Nominal Cross sectional area Reference conductor diameter Nominal insulation thickness Nominal diameter over insulation Nominal screen area on each core Number and nominal diameter of screen wires Nominal over screen wire Approx overall diameter Approx weight of cable Max.
puling tension
Min.bending radius
During pulling Set in position
mm2 mm mm mm mm2 mm mm mm kg/km KN mm mm
35 7.1 3.4 14.9 22.7 40/0.85 18.2 22.5 660 1.8 400 270
50 8.4 3.4 16.0 33.0 23/1.35 20.5 24.5 820 2.5 440 290
70 10.0 3.4 17.6 45.9 32/1.35 22.0 26.5 1050 3.5 470 310
95 11.7 3.4 19.5 61.5 43/1.35 23.8 28.0 1300 4.8 500 330
120 13.2 3.4 20.8 68.7 48/1.35 25.0 26.5 1450 6.0 520 350
150 14.5 3.4 22.2 68.7 48/1.35 26.5 31.0 1555 7.5 550 370
185 16.2 3.4 23.6 68.7 48/1.35 28.0 32.5 1700 9.3 580 390
240 18.4 3.4 26.0 68.7 48/1.35 30.3 35.0 1900 12.0 630 420
300 20.6 3.4 28.5 68.7 48/1.35 32.8 37.5 2150 15.0 670 450
400 23.8 3.4 31.2 68.7 48/1.35 35.8 41.0 2500 20.0 730 490
500 26.5 3.4 34.8 68.7 48/1.35 39.5 44.5 2950 25.0 800 530
630 30.0 3.4 38.5 68.7 48/1.35 43.0 48.5 3450 32.0 870 580
800 34.5 3.4 43.0 68.7 48/1.35 47.5 53.5 4055 40.0 950 640