AS/NZS Three Core 3.8/6.6KV XLPE Insulated
Description

Application:
       This cable is used for urban networks. It can be installed aerially, in conduit, on open trays and in underground ducts 
Operating temperature:
       90 & & &,,,,,
 
Voltage rating:
       3.8/6.6KV
Construction:
       Conductor: Compact round stranded copper or aluminium
       Conductor Shield: Semi-conducting tape and /or semi-conducting cross-linked polyethylene
       Insulation: Cross-linked polyethylene
       Insulation Shield: Semi-conducting cross-linked polyethylene
      Shield: Copper wire shield
       Filler: Polypropylene (Nonhygroscopic material)
       Binding Tape: Polyester and/or non-woven tape (Optional: water blocking tape)
       Armour:Galvanized steel wire
      Sheath: Black polyvinylene (Optional: polyvinyl chloride)

Insulation colour:
     The individual cores shall be identified by the colored strip tapes ,applied under the metallic shielding layer

Followed standard:
      AS/NZS1429.1,AS/NZS1125
Construction data: 
      
Copper conductor,10KA Fault Level   

 
Nominal Cross sectional area Reference conductor diameter Nominal insulation thickness Nominal diameter over insulation Nominal screen area on each core Number and nominal diameter of screen  wires Nominal over screen wire Unarmoured Steel wire armoured
Approx overall diameter Approx weight of cable Nominal diameter over armour Approx overall diameter Approx weight of cable
mm2 mm mm mm mm2 mm mm mm kg/km mm mm kg/km
16 4.8 2.5 11.0 17.0 10/0.85 14.5 36.0 1300 38.0 43.0 2950
25 6.0 2.5 12.0 25.5 15/0.85 15.5 38.0 1700 40.5 45.0 3450
35 7.1 2.5 13.0 34.0 20/0.85 16.5 40.5 2155 43.5 49.0 4400
50 8.4 2.5 14.1 49.4 29/0.85 17.5 43.0 2755 46.0 52.0 5150
70 10.0 2.5 15.7 68.1 40/0.85 19.0 47.0 3600 50.0 56.0 6300
95 11.7 2.5 17.6 68.1 40/0.85 21.0 51.5 4550 54.0 60.5 7450
120 13.2 2.5 19.2 68.1 40/0.85 22.5 55.0 5450 57.5 63.5 8500
150 14.5 2.5 20.6 68.1 40/0.85 24.0 58.5 6300 61.0 67.5 9600
185 16.2 2.5 22.2 68.1 40/0.85 25.5 62.0 7355 64.5 71.5 10900
240 18.4 2.5 24.9 68.1 40/0.85 28.5 68.0 9300 72.0 79.5 14100
300 20.6 2.5 27.6 68.1 40/0.85 31.0 74.5 11300 78.0 90.0 16600
400 23.8 2.5 30.9 68.1 40/0.85 34.5 82.0 14400 85.5 94.0 20300
  

 






















        Aluminum conductor,10KA Fault Level 
Nominal Cross sectional area Reference conductor diameter Nominal insulation thickness Nominal diameter over insulation Nominal screen area on each core Number and nominal diameter of screen  wires Nominal over screen wire Unarmoured Steel wire armoured
Approx overall diameter Approx weight of cable Nominal diameter over armour Approx overall diameter Approx weight of cable
mm2 mm mm mm mm2 mm mm mm kg/km mm mm kg/km
35 7.1 2.5 13.0 23.8 14/0.85 16.5 40.5 1400 44.0 49.0 3700
50 8.4 2.5 14.5 32.3 19/0.85 17.5 43.5 1700 46.5 52.0 4100
70 10.0 2.5 16.0 46.0 27/0.85 19.5 47.0 2100 50.0 55.5 4800
95 11.7 2.5 17.5 61.3 36/0.85 21.0 51.0 2700 54.0 60.0 5550
120 13.2 2.5 19.0 68.1 40/0.85 22.5 54.5 3050 57.0 63.0 6150
150 14.5 2.5 20.5 68.1 40/0.85 24.0 57.5 3400 60.0 66.5 6650
185 16.2 2.5 22.0 68.1 40/0.85 25.5 61.0 3850 63.5 70.0 7350
240 18.4 2.5 24.5 68.1 40/0.85 28.0 67.0 4650 70.5 78.0 9400
300 20.6 2.5 27.0 68.1 40/0.85 30.5 73.0 5500 76.5 84.0 10700
400 23.8 2.5 30.5 68.1 40/0.85 34.0 80.5 6600 84.0 92.0 12400