PRODUCTS

AS/NZS Three Core 12.7/22KV XLPE Insulated
Description

Application:
       This cable is used for urban networks. It can be installed aerially, in conduit, on open trays and in underground ducts 
Operating temperature:
       90 & & &,,,,,
 
Voltage rating:
       12.7/22KV
Construction:
       Conductor: Compact round stranded copper or aluminium
       Conductor Shield: Semi-conducting tape and /or semi-conducting cross-linked polyethylene
       Insulation: Cross-linked polyethylene
       Insulation Shield: Semi-conducting cross-linked polyethylene
      Shield: Copper wire shield
       Filler: Polypropylene (Nonhygroscopic material)
       Binding Tape: Polyester and/or non-woven tape (Optional: water blocking tape)
       Armour:Galvanized steel wire
      Sheath: Black polyvinylene (Optional: polyvinyl chloride)

Insulation colour:
     The individual cores shall be identified by the colored strip tapes ,applied under the metallic shielding layer

Followed standard:
      AS/NZS1429.1,AS/NZS1125
Construction data: 
      
Copper conductor,10KA Fault Level  

Nominal Cross sectional area

Reference conductor diameter Nominal insulation thickness Nominal diameter over insulation Nominal screen area on each core Number and nominal diameter of screen  wires Nominal over screen wire Unarmoured Steel wire armoured
Approx overall diameter Approx weight of cable Nominal diameter over armour Approx overall diameter Approx weight of cable
mm2 mm mm mm mm2 mm mm mm kg/km mm mm kg/km
35 7.1 5.5 19.5 34.0 20/0.85 23.0 55.5 3000 57.5 64.5 6100
50 8.4 5.5 20.5 49.4 29/0.85 24.0 58.5 3600 60.5 67.0 6850
70 10 5.5 22.0 68.1 40/0.85 25.5 61.5 4605 64.5 71.5 8100
95 11.7 5.5 24.0 68.1 40/0.85 27.5 67.0 5605 68.5 75.5 9350
120 13.2 5.5 25.5 68.1 40/0.85 29.0 70.0 6500 73.5 80.5 11400
150 14.5 5.5 27.0 68.1 40/0.85 30.5 73.5 7500 77.0 84.5 12700
185 16.2 5.5 29.0 68.1 40/0.85 32.0 77.0 8550 80.5 88.0 14000
240 18.4 5.5 31.5 68.1 40/0.85 34.5 82.5 10600 86.0 93.5 16400
300 20.6 5.5 34.0 68.1 40/0.85 37.0 88.5 12700 91.5 100.0 19000
400 23.8 5.5 36.5 68.1 40/0.85 40.0 95.5 15700 98.0 107.0 22600
500 26.8 5.5 39.5 68.1 40/0.85 43.0 102.0 19100 105.0 114.0 26400

      Aluminum conductor,10KA Fault Level 
Nominal Cross sectional area Reference conductor diameter Nominal insulation thickness Nominal diameter over insulation Nominal screen area on each core Number and nominal diameter of screen  wires Nominal over screen wire Unarmoured Steel wire armoured
Approx overall diameter Approx weight of cable Nominal diameter over armour Approx overall diameter Approx weight of cable
mm2 mm mm mm mm2 mm mm mm kg/km mm mm kg/km
35 7.1 5.5 19.5 23.8 14/0.85 23.0 55.5 2250 58.0 65.0 5350
50 8.4 5.5 20.5 32.3 19/0.85 24.0 58.5 2600 61.0 68.0 5850
70 10 5.5 22.0 46.0 27/0.85 25.5 62.0 3100 65.0 71.5 6650
95 11.7 5.5 24.0 61.3 36/0.85 27.5 66.0 3700 68.0 46.0 7510
120 13.2 5.5 25.5 68.1 40/0.85 29.0 69.5 4150 72.5 80.0 9000
150 14.5 5.5 27.0 68.1 40/0.85 30.5 73.0 4600 76.0 83.5 9750
185 16.2 5.5 29.0 68.1 40/0.85 32.0 46.0 5050 79.5 87.5 10400
240 18.4 5.5 31.5 68.1 40/0.85 34.5 81.5 5850 84.5 93.0 11600
300 20.6 5.5 34.0 68.1 40/0.85 37.0 87.5 6850 90.5 99.0 13000
400 23.8 5.5 36.5 68.1 40/0.85 40.0 94.0 8000 97.0 106.0 14800
500 26.8 5.5 39.5 68.1 40/0.85 43.0 103.0 9600 105.0 114.0 17000